<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-17 17-23-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 55 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 4.0 kHz -5 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 84 kHz 8936 69,1361
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,4 dBr 7,51 dBr 7,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 17:23, 17.02.2025
RT
"GABRY PONTE, SEAN PAUL, NATTI NATASHA - Born To Love Ya "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (53 dBuV) Max at: 84 kHz MIN: 10 kHz % above 75 kHz: 69,1361 Acquired: 2025/02/17 17:22:09 Total samples: 8936 Equivalent time: 0:07:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 7,9 dBr MIN: 6,4 dBr AVE: 7,51 dBr % above 10,0 dBr: 0,0 Last value: 7,5 dBr (2025/02/17 17:22:09) Station: 96.90 MHz, signal: 4/5 (54 dBuV) 17:15 17:16 17:17 17:18 17:19 17:20 17:21 17:22 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality